Troubleshooting HMS – Incorrect Weather, Motion or Wave Radar Values
Guided checks for incorrect, unstable or offset roll, dew point, weather or wave radar readings in the Helideck Monitoring System (HMS).
Overview
This article provides structured troubleshooting guidance for situations where the Helideck Monitoring System (HMS) displays:
- Incorrect or offset roll, pitch or heave values
- Unrealistic or unstable weather readings (wind, temperature, dew point, pressure, etc.)
- Wave radar alarms, missing data or under-reported wave height
- Values that do not match expectations or local reference instruments
This guide is intended for on-site personnel performing initial diagnostics before escalating to WISE Group Support.
This article does not authorise modification of calibration, compensation, alignment or radar configuration parameters.
Who This Is For
Primary audience:
- Helideck crew
- Marine crew
- Site operators
- Offshore technicians
This article assumes:
- HMS is already installed and commissioned
- You have operator-level access to the HMS interface
- You are authorised to perform visual inspections in accordance with site procedures
Prerequisites
Before using this article:
- Review: What to do if the system is not operating as expected
- Ensure you have access to the HMS main interface, alarm/status pages, and sensor diagnostic pages (if available at your access level)
- Follow all local safety and permit-to-work procedures before accessing sensors or masts
Operational Impact and Risks
Helideck monitoring data is operationally safety-critical.
Incorrect motion or weather data may affect:
- Helideck availability status
- Flight crew landing decisions
- Operational and regulatory reporting
- Recorded historical data
Important:
- Do not modify MRU, compensation, offset, scaling or radar tuning parameters unless instructed in writing by WISE Group
- Do not attempt sensor recalibration
- Do not approach active radar equipment unless isolation has been confirmed according to site procedure
- Do not perform work at height or on exposed decks without proper authorisation and fall protection
If at any point you are unsure, stop and escalate.
Step-by-Step Troubleshooting
Step 1 – Define the Problem Clearly
Before changing or investigating anything, determine:
- Which values are affected?
- Motion: roll, pitch, heave
- Weather: wind, temperature, humidity, dew point, pressure, visibility
- Wave radar: wave height, significant wave height, wave period
- Is it one sensor only, all weather sensors, motion and weather, or multiple unrelated devices?
- When did it start?
- After restart or power interruption
- After maintenance or a software/configuration change
- After heavy weather
- Gradually over time
Record this information before proceeding.
Step 2 – Check HMS System Status
In the HMS interface:
- Open the main status page and confirm the system is not in a “System Fault”, “Degraded” or communication failure state
- Open the alarm list and identify active alarms, latched/historical alarms and device-specific warnings
If multiple unrelated sensors are in alarm simultaneously, suspect a power supply, network or communication issue rather than individual sensor failures. Do not assume all sensors have failed at once.
Step 3 – Perform Safe Visual Inspection (if permitted)
Only proceed if safe and authorised. Check for:
- Ice, snow, salt build-up or contamination
- Bird fouling
- Loose mounts or visible misalignment
- Damaged cabling or glands
- Structural corrosion or movement
- New physical obstructions near sensors or wave radar
For wave radar specifically:
- Confirm clear line of sight to the water surface
- Do not rely on appearance alone to determine whether the radar is transmitting
- Follow site RF safety procedures before approaching
If structural damage or water ingress is suspected, stop and report through your normal maintenance channel.
Step 4 – Compare Raw vs Processed Values (if available)
Motion (roll / pitch / heave)
Open the motion or MRU diagnostics page and identify raw MRU input values and processed HMS output values.
- Raw values look reasonable but processed values are offset → possible configuration or compensation issue
- All axes equally incorrect → possible alignment or sign configuration issue
- Values jump intermittently → possible cabling or sensor fault
Do not change compensation settings. If double compensation is suspected (MRU + HMS both applying correction), document current settings and contact WISE Group.
Weather and Dew Point
If dew point appears incorrect:
- Check measured temperature and relative humidity — dew point is calculated from both, so if either is incorrect, dew point will also be incorrect
- Check whether any software updates or configuration changes were made recently, as these can affect display behaviour
- Compare with a nearby reference instrument for a gross comparison only
A stable offset (e.g. always +2°C) suggests calibration drift. Random spikes suggest noise or an intermittent connection. Do not adjust offsets.
Wave Radar
Open the wave radar status page and note alarm codes, quality indicators and current reported wave height.
If wave height is consistently under-reported:
- Check for physical obstruction or new structures near the sensor
- Check for recent structural changes in the vicinity
- Record sea state conditions at the time of the reading
Radar tuning is system-specific. Do not modify parameters.
Validation – What “Good” Looks Like
After completing checks, readings can be considered stable if:
- No active sensor communication alarms
- No data quality flags (invalid, clipped, out of range)
- Stable readings over at least 5–10 minutes
- Reasonable agreement with environmental conditions
- Motion behaviour consistent with vessel movement
If values remain clearly incorrect after these checks, escalate to WISE Group Support.
Quick Reference: Symptom → Possible Cause → Action
|
Symptom |
Possible Cause |
Action |
|
All weather values incorrect |
Power or communication issue |
Check system status and alarms |
|
Roll offset but stable |
Compensation or alignment configuration |
Document and escalate to WISE Group |
|
Roll unstable or jumping |
Intermittent MRU connection |
Check alarms and cabling visually |
|
Dew point unrealistic |
Faulty temperature or humidity sensor, or recent software/config change |
Check base sensor inputs and recent change log |
|
Wave radar under-reading |
Obstruction, alignment issue, or structural change near sensor |
Perform visual inspection |
|
Multiple unrelated alarms |
Power or network fault |
Escalate as system-level issue |
When Contacting WISE Group Support
Please provide the following to reduce response time and improve diagnostic accuracy:
- Clear description of the issue and when it started
- Screenshots of the main status page, alarm list and relevant diagnostic page
- Example time-stamped readings
- Notes on any recent maintenance, software updates or configuration changes
- Photos (if safe and permitted)
FAQ
Can I adjust motion offsets if roll appears incorrect?
No. Do not modify MRU or HMS compensation parameters without written instruction from WISE Group.
Can I recalibrate weather sensors on site?
No. Field recalibration is not covered in this article and must be carried out by a qualified WISE Group engineer.
Why does dew point look wrong when temperature seems correct?
Check the relative humidity input. Dew point is calculated from both temperature and humidity, so an error in either will affect the result. Also check whether any recent software or configuration changes coincide with when the issue appeared.
What if I suspect double motion compensation?
Do not attempt to change any settings. Document what you are seeing — particularly whether raw MRU values look correct but processed values appear doubled — and contact WISE Group with this information.
Related Articles
- What to do if the system is not operating as expected
- Annual and Remote Service for HMS and EMS Systems
- The Difference Between Sensor Calibration and System Verification
- Routine Sensor Inspection and Care
Still have questions?
Submit a support ticket through the Customer Support Portal or Submit Support Ticket form.